Fronius Primo-5.0-1 Solar inverter Primo-5.0-1 4.210.063
Fronius

Fronius Primo-5.0-1 Solar inverter Primo-5.0-1 4.210.063

Normaler Preis €1,159.58 €0.00
Fronius Primo-5.0-1 Solar inverter Primo-5.0-1
successor ofFronius Ig Plus 55V-1 Solar inverter


!! not suitable for DE !!

The communicative inverter for optimized energy management.

With performance classes of 3.0 to 8.2 kW rounds the Fronius Primo The new snapinverter inverter generation perfectly off. The single-phase, trafolose device is the ideal inverter for private households.

the Fronius Primo has an above-average increase in input voltage range - maximum flexibility in plant design is safe. For single-phase systems, it is the perfect repowering inverter.

Technical specifications


Input data Fronius Primo 5.0-1 Fronius Primo 5.0-1 out
Max. Input current
(IDC Max 1 / IDC Max 2 )
12.0 A / 12.0 A 18.0 A / 18.0 A
Max. Short circuit module field
(MPP1/ Mpp2)
18.0 A / 18.0 A 27.0 A / 27.0 A
Min. Input voltage
(UDC min)
80V
Infeed start voltage (UDC Start) 80V
Nominal input voltage (UDC, R) 710 V
Max. Input voltage (UDC Max) 1,000 V
MPP voltage range (UMpp min - umpp max) 240 - 800 V
Number of Mpp Tracker 2
Number of DC connections 2+2
Max. PV generator power (PDC Max) 7.5 kWpeak
Output data    
AC nominal power (PAC, R) 5,000 W 4,600 W
Max. Output power 5,000 VA 5,000 VA
AC output current (IAC nom) 21.7 A 21.7 A
Mains connection (voltage range) 1 ~ NPE 220 V / 230 V (180 V - 270 V)
Frequency (frequency range) 50 Hz / 60 Hz (45 - 65 Hz)
Clank factor < 5 %
Power factor (Cos φAC, R) 0.85 - 1 IND. / Cap.
GENERAL DATA    
Dimensions (height x width x depth) 645 x 431 x 204 mm
Weight 21.5 kg
Class IP 65
Protection class 1
Overvoltage category (DC / AC)1) 2 / 3
Night consumption <1 W
Inverter concept Trafolos
cooling Regulated air cooling
Assembly Indoor and outdoor assembly
Ambient temperature range -40 - +55 ° C
Permissible humidity 0 - 100 %
Max. Height over sea level 4,000 m
Connection technology DC 4x DC + and 4x DC screw terminals 2.5 - 16 mm²
Connection technology AC 3 pole AC screw terminals 2.5 - 16 mm²
Certificates and Nursing Filling DIN VE VDE 0126-1-1 / A1, IEC 62109-1 / -2, IEC 62116, IEC 61727,
AS 4777-2, AS 4777-3, G83 / 2, G59 / 3, CEI 0- 21, VDE AR ​​N 4105 2)
Efficiency    
Max. Efficiency 98,0 % 98,0 %
European Efficiency (ηEU) 97,1 % 97,1 %
η at 5% pAC, R3) 80,8 / 82,5 / 82,5 % 80,8 / 82,5 / 82,5 %
η at 10% pAC, R3) 89,6 / 94,8 / 93,1 % 89,6 / 94,8 / 93,1 %
η at 20% pAC, R3) 93,4 / 97,2 / 96,2 % 93,4 / 97,2 / 96,2 %
η at 25% pAC, R3) 94,1 / 97,3 / 96,8 % 94,1 / 97,3 / 96,8 %
η at 30% PAC, R3) 94,7 / 97,4 / 97,0 % 94,7 / 97,4 / 97,0 %
η at 50% pAC, R3) 95,8 / 97,9 / 97,7 % 95,8 / 97,9 / 97,7 %
η at 75% pAC, R3) 96,1 / 98,0 / 97,9 % 96,1 / 98,0 / 97,9 %
η at 100% pAC, R3) 96,2 / 97,9 / 97,9 % 96,2 / 97,9 / 97,9 %
MPP adaptation efficiency > 99,9 %
SAFETY DEVICES    
DC isolation measurement

Diesen Artikel teilen


Mehr aus dieser Sammlung