Fronius Primo-5.0-1 Solar inverter Primo-5.0-1 4.210.063
successor ofFronius Ig Plus 55V-1 Solar inverter
!! not suitable for DE !!
The communicative inverter for optimized energy management.
With performance classes of 3.0 to 8.2 kW rounds the Fronius Primo The new snapinverter inverter generation perfectly off. The single-phase, trafolose device is the ideal inverter for private households.
the Fronius Primo has an above-average increase in input voltage range - maximum flexibility in plant design is safe. For single-phase systems, it is the perfect repowering inverter.
Technical specifications
Input data | Fronius Primo 5.0-1 | Fronius Primo 5.0-1 out |
---|---|---|
Max. Input current (IDC Max 1 / IDC Max 2 ) |
12.0 A / 12.0 A | 18.0 A / 18.0 A |
Max. Short circuit module field (MPP1/ Mpp2) |
18.0 A / 18.0 A | 27.0 A / 27.0 A |
Min. Input voltage (UDC min) |
80V | |
Infeed start voltage (UDC Start) | 80V | |
Nominal input voltage (UDC, R) | 710 V | |
Max. Input voltage (UDC Max) | 1,000 V | |
MPP voltage range (UMpp min - umpp max) | 240 - 800 V | |
Number of Mpp Tracker | 2 | |
Number of DC connections | 2+2 | |
Max. PV generator power (PDC Max) | 7.5 kWpeak | |
Output data | ||
AC nominal power (PAC, R) | 5,000 W | 4,600 W |
Max. Output power | 5,000 VA | 5,000 VA |
AC output current (IAC nom) | 21.7 A | 21.7 A |
Mains connection (voltage range) | 1 ~ NPE 220 V / 230 V (180 V - 270 V) | |
Frequency (frequency range) | 50 Hz / 60 Hz (45 - 65 Hz) | |
Clank factor | < 5 % | |
Power factor (Cos φAC, R) | 0.85 - 1 IND. / Cap. | |
GENERAL DATA | ||
Dimensions (height x width x depth) | 645 x 431 x 204 mm | |
Weight | 21.5 kg | |
Class | IP 65 | |
Protection class | 1 | |
Overvoltage category (DC / AC)1) | 2 / 3 | |
Night consumption | <1 W | |
Inverter concept | Trafolos | |
cooling | Regulated air cooling | |
Assembly | Indoor and outdoor assembly | |
Ambient temperature range | -40 - +55 ° C | |
Permissible humidity | 0 - 100 % | |
Max. Height over sea level | 4,000 m | |
Connection technology DC | 4x DC + and 4x DC screw terminals 2.5 - 16 mm² | |
Connection technology AC | 3 pole AC screw terminals 2.5 - 16 mm² | |
Certificates and Nursing Filling | DIN VE VDE 0126-1-1 / A1, IEC 62109-1 / -2, IEC 62116, IEC 61727, AS 4777-2, AS 4777-3, G83 / 2, G59 / 3, CEI 0- 21, VDE AR N 4105 2) |
|
Efficiency | ||
Max. Efficiency | 98,0 % | 98,0 % |
European Efficiency (ηEU) | 97,1 % | 97,1 % |
η at 5% pAC, R3) | 80,8 / 82,5 / 82,5 % | 80,8 / 82,5 / 82,5 % |
η at 10% pAC, R3) | 89,6 / 94,8 / 93,1 % | 89,6 / 94,8 / 93,1 % |
η at 20% pAC, R3) | 93,4 / 97,2 / 96,2 % | 93,4 / 97,2 / 96,2 % |
η at 25% pAC, R3) | 94,1 / 97,3 / 96,8 % | 94,1 / 97,3 / 96,8 % |
η at 30% PAC, R3) | 94,7 / 97,4 / 97,0 % | 94,7 / 97,4 / 97,0 % |
η at 50% pAC, R3) | 95,8 / 97,9 / 97,7 % | 95,8 / 97,9 / 97,7 % |
η at 75% pAC, R3) | 96,1 / 98,0 / 97,9 % | 96,1 / 98,0 / 97,9 % |
η at 100% pAC, R3) | 96,2 / 97,9 / 97,9 % | 96,2 / 97,9 / 97,9 % |
MPP adaptation efficiency | > 99,9 % | |
SAFETY DEVICES | ||
DC isolation measurement |